Zhaoxing Ma , Hao Chen , Yanli Chai
2017, 2(3):211-219. DOI: 10.1186/s41601-017-0051-3
Abstract:Wind speed follows the Weibull probability distribution and wind power can have a significant influence on power system voltage stability. In order to research the influence of wind plant correlation on power system voltage stability, in this paper, the stochastic response surface method (SRSM) is applied to voltage stability analysis to establish the polynomial relationship between the random input and the output response. The Kendall rank correlation coefficient is selected to measure the correlation between wind farms, and the joint probability distribution of wind farms is calculated by Copula function. A dynamic system that includes system node voltages is established. The composite matrix spectral radius of the dynamic system is used as the output of the SRSM, whereas the wind speed is used as the input based on wind farm correlation. The proposed method is compared with the traditional Monte Carlo (MC) method, and the effectiveness and accuracy of the proposed approach is verified using the IEEE 24-bus system and the EPRI 36-bus system. The simulation results also indicate that the consideration of wind farm correlation can more accurately reflect the system stability.
2017, 2(3):220-228. DOI: 10.1186/s41601-017-0052-2
Abstract:The operation mode of power grids with intermittent distributed generations (DGs) changes frequently due to the bidirectional power flow. In comparison with the conventional grids, the protection relays in power grids with micro-sources are more difficult to set. To tackle this problem, this paper proposes an extended bus differential protection (EBDP) strategy based on the limited wide area (LWA). In this method, the micro-grids are divided into several protection areas at the core of the bus. The whole protection areas are protected by the wide area current differential relays, which are also configured to protect each component in this protection area. Moreover, the protection areas can be changed adaptively according to the power flow direction. Finally, a micro-grid model with multiple DGs is developed using the PSCAD/EMTDC platform. The simulation results indicate that the proposed adaptive limited wide area differential protection (LWADP) has better performance than the traditional relaying protection in detecting the faulty area in micro-grids and isolating the fault, and can be widely utilized in larger micro-grids.
B. Mallikarjuna , P. V. Vardhan Varma , S. D. Samir , M. Jaya Bharata Reddy , D. K. Mohanta
2017, 2(3):229-244. DOI: 10.1186/s41601-017-0053-1
Abstract:Maloperation of conventional relays is becoming prevalent due to ever increase in complexity of conventional power grids. They are dominant during power system contingencies like power swing, load encroachment, voltage instability, unbalanced loading, etc. In these situations, adaptive supervised wide-area backup protection (ASWABP) plays a major role in enhancing the power system reliability. A balance between security and dependability of protection is essential to maintain the reliability. This paper proposes multi-phasor measurement units (MPMU) based ASWABP scheme that can function effectively during faults besides power system contingencies. MPMU is an extended version of Phasor Measurement Unit (PMU). It is an intelligent electronic device which estimates the synchronized predominant harmonic phasors (100Hz and 150Hz) along with the fundamental phasors (50Hz) of three phase voltages and currents with high precision. The proposed ASWABP scheme can detect the fault, identify the parent bus, determine the faulty branch and classify the faults using MPMU measurements at System Protection Center (SPC). Based on these MPMU measurements (received at phasor data concentrator (PDC) at SPC) the appropriate relays will be supervised to enhance the overall reliability of the power grid. Numerous case studies are conducted on WSCC-9 bus and IEEE-14 bus systems to illustrate the security and dependability attributes of proposed ASWABP scheme in MATLAB/Simulink environment. Also, comparative studies are performed with the existing conventional distance protection (Mho relays) for corroborating the superiority of the proposed scheme regarding security and dependability. Comparative studies have shown that the proposed scheme can be used as adaptive supervised wide-area backup protection of conventional distance protection.
Fahad Iqbal , Anwar Shahzad Siddiqui
2017, 2(3):245-256. DOI: 10.1186/s41601-017-0055-z
Abstract:The foremost issues of 21st century are challenging demand of electrical energy and to control the emission of Green House Gases (GHG) emissions. Renewable energy resources based sustainable microgrid emerges as one of the best feasible solution for future energy demand while considering zero carbon emission, fossil fuel independency, and enhanced reliability. In this paper, optimization and implementation of institutional based sustainable microgrid are discussed based on cost analysis, carbon emission, and availability of energy resources. Various microgrid topologies are considered for addressing the most ideal solution. The metrological data such as irradiance is acquired from solar satellite data of NASA (National Aero Space Agency) while the data for wind speed is taken from synergy enviro engineer’s site. HOMER® simulation tool is used for modelling and optimization purpose.
Magdi El-Saadawi , Ahmed Hatata
2017, 2(3):257-268. DOI: 10.1186/s41601-017-0057-x
Abstract:This paper proposes a novel scheme for detecting and classifying faults in stator windings of a synchronous generator (SG). The proposed scheme employs a new method for fault detection and classification based on Support Vector Machine (SVM). Two SVM classifiers are proposed. SVM1 is used to identify the fault occurrence in the system and SVM2 is used to determine whether the fault, if any, is internal or external. In this method, the detection and classification of faults are not affected by the fault type and location, pre-fault power, fault resistance or fault inception time. The proposed method increases the ability of detecting the ground faults near the neutral terminal of the stator windings for generators with high impedance grounding neutral point. The proposed scheme is compared with ANN-based method and gives faster response and better reliability for fault classification.
Li Huang , Yongbiao Yang , Honglei Zhao , Xudong Wang , Hongjuan Zheng
2017, 2(3):269-275. DOI: 10.1186/s41601-017-0059-8
Abstract:Stochastic noises have a great adverse effect on the prediction accuracy of electric power load. Modeling online and filtering real-time can effectively improve measurement accuracy. Firstly, pretreating and inspecting statistically the electric power load data is essential to characterize the stochastic noise of electric power load. Then, set order for the time series model by Akaike information criterion (AIC) rule and acquire model coefficients to establish ARMA (2,1) model. Next, test the applicability of the established model. Finally, Kalman filter is adopted to process the electric power load data. Simulation results of total variance demonstrate that stochastic noise is obviously decreased after Kalman filtering based on ARMA (2,1) model. Besides, variance is reduced by two orders, and every coefficient of stochastic noise is reduced by one order. The filter method based on time series model does reduce stochastic noise of electric power load, and increase measurement accuracy.
2017, 2(3):276-293. DOI: 10.1186/s41601-017-0056-y
Abstract:Integration of electric vehicles (EVs), demand response and renewable energy will bring multiple opportunities for low carbon power system. A promising integration will be EV battery swapping station (BSS) bundled with PV (photovoltaic) power. Optimizing the configuration and operation of BSS is the key problem to maximize benefit of this integration. The main objective of this paper is to solve infrastructure configuration of BSS. The principle challenge of such an objective is to enhance the swapping ability and save corresponding investment and operation cost under uncertainties of PV generation and swapping demand. Consequently this paper mainly concentrates on combining operation optimization with optimal investment strategies for BSS considering multiscenarios PV power generation and swapping demand. A stochastic programming model is developed by using state flow method to express different states of batteries and its objective is to maximize the station’s net profit. The model is formulated as a mixed-integer linear program to guarantee the efficiency and stability of the optimization. Case studies validate the effectiveness of the proposed approach and demonstrate that ignoring the uncertainties of PV generation and swapping demand may lead to an inappropriate batteries, chargers and swapping robots configuration for BSS.
2017, 2(3):294-310. DOI: 10.1186/s41601-017-0061-1
Abstract:Emission of greenhouse gases and depletion of fossil fuel reserves are two key drivers, which are forcing the mankind to generate the future energy demand from the renewable energy resources. These resources are generally distributed in nature and are directly integrated at distribution levels. Increasing penetration of the distributed energy resources in distribution power networks creates additional operational and control issues. These are mostly regulatory, economical load dispatching, power quality and protection issues. Generally power distribution systems are protected with the help of dedicated over current based protection schemes. But increasing share of distributed energy resources penetration in electric utilities poses a serious threat to the existing protection coordination schemes of the distribution systems. Distributed energy resources connected distribution networks become interconnected in nature and protection coordination schemes, which are designed for unidirectional flow of fault currents become ineffective/non-functional. Therefore, new protection coordination schemes are required for providing the adequate protection coordination for distributed energy resources connected electric power networks. In the available literature, the protection coordination schemes for radial distribution systems and developments in the area of protection coordination are discussed in detail. A thorough review for all these protection coordination schemes for distribution systems with and without distributed energy resources is done in this review article. It includes the analytical and artificial intelligence based techniques application for coordination of protective relays in the distribution systems. The limitations and research gaps in the area of protection coordination schemes are also presented in this review article. The aim of this research paper is to bring all the available research in the area of relay coordination on one platform, so that it will help the emerging researcher to identify the future scope of relay coordination application for distributed energy resources connected distribution systems.
Renfeng Tao , Fengting Li , Weiwei Chen , Yanfang Fan , Chenguang Liang , Yang Li
2017, 2(3):311-319. DOI: 10.1186/s41601-017-0050-4
Abstract:To coordinate the protection of PMSG (permanent magnet synchronous generator), collector circuits and outgoing lines, a comprehensive and improved protection method of PMSG based wind farms with LVRT (low voltage ride through) capability is proposed. The proposed method includes adding a short time delay to the collector network current protection zone I and a directional protective relaying to the collector network protection, installing grounding transformers and zero sequence current protection, and generator low-voltage protection action improvement. A LVRT scheme consisting of variable resistance dumping circuit, grid side dynamic reactive power control and reactive power compensation control is proposed. The fault characteristics of PMSG based wind farms are analyzed, and a PMSG based wind farm in Dabancheng, Xinjiang, is used as an example to analyze typical wind farm protection configuration, the setting values considering LVRT requirements, and the coordination problems. Finally, an improved wind farm protection coordination methodology is proposed and its validity is verified by simulation.