基于激磁电流单周期内负半波持续时间特征的直流剩余电流检测新型相位差法
CSTR:
作者:
作者单位:

(1.天津大学智能电网教育部重点实验室,天津 300072;2.天津市电力系统仿真控制重点实验室,天津 300072; 3.国网江苏省电力有限公司电力科学研究院,江苏 南京 211103)

作者简介:

王守相(1973—),男,博士,教授,研究方向为智能配电系统分析、分布式发电系统分析与仿真;E-mail: sxwang@ tju.edu.cn 李皓哲(1996—),男,硕士研究生,通信作者,研究方向为低压直流用电系统剩余电流保护;E-mail: lihaozhe2019@ 163.com 刘 琪(1992—),男,博士研究生,研究方向为直流配电系统故障暂态机理分析。E-mail: liuqi_tj@tju.edu.cn

通讯作者:

中图分类号:

基金项目:

国家重点研发计划项目资助(2018YFB0904700)


A new phase difference method for DC residual current detection based on the characteristic of the duration of the exciting current negative half wave in a period
Author:
Affiliation:

(1. Key Laboratory of Smart Grid of Ministry of Education, Tianjin University, Tianjin 300072, China; 2. Tianjin Key Laboratory of Power System Simulation and Control, Tianjin 300072, China; 3. State Grid Jiangsu Electric Power Co., Ltd. Research Institute, Nanjing 211103, China)

Fund Project:

  • 摘要
  • |
  • 图/表
  • |
  • 访问统计
  • |
  • 参考文献
  • |
  • 相似文献
  • |
  • 引证文献
  • |
  • 资源附件
  • |
  • 文章评论
    摘要:

    针对直流剩余电流保护方法中传统的相位差法存在检测特征提取困难和硬件电路结构复杂的问题,提出了一种基于激磁电流一个周期内负半波持续时间特征的直流剩余电流检测新型相位差法。该方法通过检测激磁电流负半波的持续时间在剩余电流出现前后的差值来检测直流剩余电流。首先对激磁电流进行半波整流处理,将其负半波的持续时间转化为其幅值为零的时间。然后通过检测其幅值为零的持续时间在剩余电流出现前后的差值达到测量目的。基于该方法完成了直流剩余电流互感器硬件电路的设计,并通过实验验证了此方法的有效性。

    Abstract:

    The traditional phase difference method finds it difficult to extract detection features and the hardware circuit structure is complex in the DC residual current protection method. Thus a new phase difference method for DC residual current detection based on the characteristic of the duration of the exciting current negative half wave in a period is proposed. In this method, the difference between the duration of negative half wave of excitation current before and after the appearance of residual current is detected to detect DC residual current. First, the excitation current is rectified by half wave, and the duration of negative half wave is converted into the duration of zero amplitude excitation current. Then, the difference between the duration before and after the appearance of residual current is detected to achieve the purpose of measurement. Based on this method, the hardware circuit of a DC residual current transformer is designed, and the effectiveness of this method is verified by experiment. This work is supported by the National Key Research and Development Program of China (No. 2018YFB0904700).

    参考文献
    相似文献
    引证文献
引用本文

王守相,李皓哲,刘 琪,等.基于激磁电流单周期内负半波持续时间特征的直流剩余电流检测新型相位差法[J].电力系统保护与控制,2021,49(11):45-53.[WANG Shouxiang, LI Haozhe, LIU Qi, et al. A new phase difference method for DC residual current detection based on the characteristic of the duration of the exciting current negative half wave in a period[J]. Power System Protection and Control,2021,V49(11):45-53]