    摘要:

    多端口级联式电力电子变压器(Power Electronic Transformer, PET)是未来实现多电压等级、交直流混联形态配电网的核心设备,其可靠性对于配电网可靠性水平影响较大。首先分析了多端口级联式PET典型拓扑结构及工作原理。其次基于工程可靠性原理研究建立了考虑器件冗余的PET可靠性评估模型。然后分析了PET对交直流混合配电网可靠性的影响。最后针对某“手拉手”结构交直流混合配电网进行算例分析。计算了PET不同设计模式、冗余度下的可靠性水平。进行了PET对交直流混合配电系统可靠性的影响及其灵敏度分析,验证了所提算法的正确性和有效性。

    Abstract:

    The cascaded multiport Power Electronic Transformer (PET) is a key equipment for future distribution grid with multi-voltage level and AC/DC hybrid feature, whose reliability has significant effect on the distribution grid reliability level. First, the typical topological structure and working principle of cascaded multiport PET are analyzed. Secondly, the reliability evaluation model for PET considering the device redundancy is established based on the engineering reliability theory. Then the effect of cascaded multiport PET on the AC/DC hybrid distribution network reliability is analyzed. Finally, the case studies are provided with a ‘hand in hand’ AC/DC hybrid power distribution network structure. The PET reliability levels under different design patterns and the redundancy levels are calculated. The influence of PET on reliability of AC/DC hybrid distribution system and its sensitivity analysis are carried out, which verifies the correctness and validity of the proposed algorithm. This work is supported by Science and Technology Project of China Southern Power Grid Co., Ltd. (No. GDKJQQ20161200).