基于集对分析和风险理论的变电站主接线综合评价
CSTR:
作者:
作者单位:

(1.华北电力大学新能源电力系统国家重点实验室,河北 保定 071003; 2.广东电网有限责任公司电力调度控制中心,广东 广州 510600)

作者简介:

栗 然(1965—),女,博士,教授,研究方向为新能源与并网技术、电力系统分析、运行与控制;E-mail:liranlelele@ 163.com
李永彬(1990—),男,通信作者,硕士研究生,研究方向为电力系统分析、运行与控制;E-mail:lyb0207@126.com
翟晨曦(1993—),女,硕士研究生,研究方向为电力系统分析、运行与控制。

通讯作者:

中图分类号:

基金项目:

广东电网有限责任公司电力调度控制中心科技项目资助


Comprehensive evaluation of substation main connection based on set pair analysis and risk theory
Author:
Affiliation:

(1. State Key Laboratory of Alternate Electrical Power System with Renewable Energy Sources, North China Electric Power University, Baoding 071003, China;2. Power Dispatch Control Centre of Guangdong Power Grid Corp. Ltd., Guangzhou 510600, China)

Fund Project:

  • 摘要
  • |
  • 图/表
  • |
  • 访问统计
  • |
  • 参考文献
  • |
  • 相似文献
  • |
  • 引证文献
  • |
  • 资源附件
  • |
  • 文章评论
    摘要:

    新《调规》着重强调了负荷对于电网的重要性,因此在评估和选择变电站主接线时,有必要从电网层面评估不同变电站主接线形式的失负荷风险。针对变电站主接线评价过程中的不确定性信息,提出一种基于集对分析和风险理论的变电站主接线综合评价方法。该方法首先从电网层面对变电站主接线进行风险评估,将评估结果作为变电站主接线的可靠性评价指标。然后利用改进熵权法得到各评价指标的权重系数,通过集对分析法对评价方案进行不确定性分析。最后综合一次、二次排序的结果选出最优方案。算例验证表明,集对分析方法决策过程简单直观,用于变电站主接线综合评价具有良好的不确定性信息处理能力,从而为工作人员在评估变电站主接线时提供一定的参考和依据。

    Abstract:

    The new publishment of the Rule No. 599 puts more emphasis on the importance of customers to the power grid, so it is necessary to assess the risk of load-shedding from the perspective of power grid in the assessment and selection of main connection. Aiming at the uncertainty information in the evaluation process of substation main connection, this paper presents a comprehensive evaluation method of substation main connection based on set pair analysis and risk theory. The method evaluates the risk of substation main connection from the perspective of network layer firstly, and its results are used as the reliability evaluation indices of substation main connection. Then the weight coefficients of evaluation indices are obtained by improved entropy weight method, meanwhile, the uncertainty analysis is carried out by set pair analysis. Finally, the optimal scheme is selected by integrating the results of first and second order. Numerical examples show that the process of set pair analysis method is simple and intuitive. When used in substation main connection comprehensive evaluation, set pair analysis method is capable of processing uncertainty information easily, therefore it can provide some reference and basis for designers to select the substation main connection. This work is supported by Power Dispatch Control Centre of Guangdong Power Grid Corp. Ltd.

    参考文献
    相似文献
    引证文献
引用本文

栗然,李永彬,翟晨曦,等.基于集对分析和风险理论的变电站主接线综合评价[J].电力系统保护与控制,2017,45(11):81-88.[LI Ran, LI Yongbin, ZHAI Chenxi, et al. Comprehensive evaluation of substation main connection based on set pair analysis and risk theory[J]. Power System Protection and Control,2017,V45(11):81-88]

复制
分享
相关视频

文章指标
  • 点击次数:
  • 下载次数:
  • HTML阅读次数:
  • 引用次数:
历史
  • 收稿日期:2016-03-31
  • 最后修改日期:2016-08-25
  • 录用日期:
  • 在线发布日期: 2017-05-31
  • 出版日期:
文章二维码