    摘要:

    采用LCL滤波器作为电压型并网逆变器与电网的接口,建立LCL滤波器的数学模型,提出一种基于电网侧电流外环、逆变器侧电流内环的LCL并网逆变器控制方法。该控制方法既能有效保护功率开关,又能保证系统稳定及并网电流的单位功率因数。针对该电流双闭环控制方法,给出一种基于赫尔维茨稳定判据及李纳德-戚帕特稳定判据的内外环控制器参数设计方案。进行了LCL并网逆变器并网运行仿真与实验。仿真和实验结果验证了所提LCL并网逆变器控制方法的正确性和可行性。

    Abstract:

    A LCL filter is adopted as an interface between grid-connected inverter and power grid. The mathematical model of the LCL filter is built, and then a control method for grid-connected inverter with a LCL filter is proposed. This control method employs an external grid-side current loop and an internal inverter-side current loop. And this control method can not only protect power switches effectively, but also ensure the system stability and high in-grid power factor. Based on the Hurwitz stability criterion and Lienard Chipart stability criterion, the design method of controller parameters in inner and outer loops is derived. Simulations and experiments of grid-connected inverter in grid-connected mode are conducted. Simulation and experimental results validate the correctness and feasibility of the proposed method. This work is supported by National Natural Science Foundation of China (No. 51207156).