大型移动式光伏电站防孤岛能力检测平台的研究与开发
CSTR:
作者:
作者单位:

(1.国网河北省电力公司电力科学研究院,河北 石家庄 050021;2.华北电力大学
新能源电力系统国家重点实验室,河北 保定 071003)

作者简介:

胡文平(1968-),男,博士,高工,主要研究领域为电网分析与计算、电能质量和分布式能源;
雷胜华(1990-),男,通信作者,硕士研究生,研究方向为电力系统继电保护与控制;E-mail:leishenghua1014@ qq.com
王 雪(1978-),男,博士,讲师,研究方向为电力系统继电保护与控制。

通讯作者:

中图分类号:

基金项目:

国网河北省电力公司科技项目(KJ2014-052)


Design and development of the mobile platform to test the ability of anti-islanding for large-scale PV power station
Author:
Affiliation:

(1. Electric Power Research Institute, State Grid Electric Power Company of Hebei Province, Shijiazhuang 050021, China;
;2. State Key Laboratory of Alternate Electrical Power System with Renewable Energy Sources,
North China Electric Power University, Baoding 071003, China)

Fund Project:

  • 摘要
  • |
  • 图/表
  • |
  • 访问统计
  • |
  • 参考文献
  • |
  • 相似文献
  • |
  • 引证文献
  • |
  • 资源附件
  • |
  • 文章评论
    摘要:

    根据近年来我国光伏发电产业的发展现状以及光伏电站并网标准的相关规定,针对开展防孤岛能力试验需要考虑的逆变器容量、并网点电压等级、负荷加载、地理环境等实际问题,开发了一套具有380 V/ 10 kV/35 kV多电压等级接入、最大容量为1.5 MW的移动式光伏电站防孤岛能力检测平台。该平台能够满足不同类型光伏电源防孤岛能力试验的需要。选定曲阳县某光伏电站开展现场防孤岛能力检测试验。试验结果证明该检测平台能快速、准确地检测到并网逆变器是否具有防孤岛能力。

    Abstract:

    According to the current development of photovoltaic industry and the relevant provisions of the standards for PV power station connected to power grid in recent years, a testing platform to detect the ability of anti-islanding is developed and designed. The mobile an-islanding detection platform can be accessed to a set of multi-voltage, such as 380 V, 10 kV, 35 kV, with the maximum capacity of PV power station being 1.5 MW, considering the capacity of the inverter, power grid’s voltage level, load loaded, geographical environment and so on. Field tests have been conducted successfully on a PV power station in Quyang. The results show that whether the inverter connected to power grid owes the ability of an-islanding can be detected quickly and accurately by the test platform.