基于改进混合抽样与最小切负荷计算的电力系统可靠性评估方法
CSTR:
作者:
作者单位:

(1.电力传输与功率变换控制教育部重点实验室(上海交通大学),上海 200240;
2..中国电力科学研究院,北京 100192)

作者简介:

孙腾飞(1990-),男,通信作者,硕士研究生,主要研究方向为电力系统规划、电力系统可靠性;E-mail:soar1990@sina.com
程浩忠(1962-),男,博士,教授,博士生导师,主要研究方向为电力系统规划、无功和电压稳定、电能质量等。

通讯作者:

中图分类号:

基金项目:

国家自然科学基金重点项目(51337005);国家电网公司基础性前瞻性项目(XT71-14-002)


Reliability evaluation based on modified mixed sampling and minimum load-cutting method
Author:
Affiliation:

(1. Key Laboratory of Control of Power Transmission and Conversion, Ministry of Education (Shanghai Jiao Tong
University), Shanghai 200240, China; ;2. China Electric Power Research Institute, Beijing 100192, China)

Fund Project:

  • 摘要
  • |
  • 图/表
  • |
  • 访问统计
  • |
  • 参考文献
  • |
  • 相似文献
  • |
  • 引证文献
  • |
  • 资源附件
  • |
  • 文章评论
    摘要:

    评估组合系统可靠性时,蒙特卡罗模拟法不受系统规模及非线性的影响,且结果准确的特性使其在大型电力系统可靠性评估中具有优越性。但为了获得精度较高的可靠性指标,其往往需要较长计算时间。针对这一问题,采用重要抽样法与离散拉丁超立方抽样相结合的方法,从减小样本方差与增加样本均匀性两方面提高蒙特卡罗模拟的收敛性。对于大规模发输电系统,运用灵敏度分析与线性规划相结合的方法进行系统过负荷校正,既能保证求解最优性又可以提高求解速度。将该算法应用于IEEE RTS79系统、IEEE RTS96系统和某电网500 kV及以上电压等级电力系统计算可靠性指标,验证了该算法的可行性。

    Abstract:

    As its sampling frequency is independent of the scale of the system and non-linear performance, Monte-Carlo simulation is widely applied to reliability evaluation of a complex large transmission system because of its accurate result. However, it takes a relatively long period of time to obtain a higher accurate reliability index. In order to solve this problem, the combination of importance sampling method and discrete Latin hypercube sampling method is able to reduce the variance of the sample space and uniformly sample it simultaneously, which improves the convergence of Monte-Carlo simulation. This paper points out that, the combination of sensitivity analysis and linear programming in the process of overload correction is able to guarantee the solution optimality as well as improve the solving speed. Finally, the algorithm is presented for IEEE RTS79, IEEE RTS96 and a certain system to obtain the reliability index, the result proves its practicability. This work is supported by National Natural Science Foundation of China (No. 51337005) and Fundamental and Prospective Science and Technology Project of State Grid Corporation of China (No. XT71-14-002).

    参考文献
    相似文献
    引证文献
引用本文

孙腾飞,程浩忠,张立波,等.基于改进混合抽样与最小切负荷计算的电力系统可靠性评估方法[J].电力系统保护与控制,2016,44(13):96-103.[SUN Tengfei, CHENG Haozhong, ZHANG Libo, et al. Reliability evaluation based on modified mixed sampling and minimum load-cutting method[J]. Power System Protection and Control,2016,V44(13):96-103]

复制
分享
相关视频

文章指标
  • 点击次数:
  • 下载次数:
  • HTML阅读次数:
  • 引用次数:
历史
  • 收稿日期:2015-08-04
  • 最后修改日期:2015-11-22
  • 录用日期:
  • 在线发布日期: 2016-07-03
  • 出版日期:
文章二维码
关闭
关闭