引用本文:Xiaowei Wang,Huan Du,Jie Gao,等.[J].电力系统保护与控制,2023,(1):67-80.
Xiaowei Wang,Huan Du,Jie Gao,et al.Grounding fault location method of overhead line based on dual-axis magnetic field trajectory[J].Power System Protection and Control,2023,(1):67-80
【打印本页】   【下载PDF全文】   查看/发表评论  【EndNote】   【RefMan】   【BibTex】
←前一篇|后一篇→ 过刊浏览    高级检索
本文已被:浏览 4907次   下载 39 本文二维码信息
码上扫一扫!
分享到: 微信 更多
Xiaowei Wang, Huan Du, Jie Gao, Xiangxiang Wei, Zhenfeng Liang, Liang Guo, Weibo Liu
作者单位
Xiaowei Wang  
Huan Du  
Jie Gao  
Xiangxiang Wei  
Zhenfeng Liang  
Liang Guo  
Weibo Liu  
摘要:
关键词:  
DOI:10.1186/s41601-023-00276-z
分类号:
基金项目:This work was supported in part by the National Natural Science Foundation of China (52177114, 61403127) and Jiangxi Electric Power Co., Ltd of State Grid (521820210005, 521820220016).
Grounding fault location method of overhead line based on dual-axis magnetic field trajectory
Xiaowei Wang, Huan Du, Jie Gao, Xiangxiang Wei, Zhenfeng Liang, Liang Guo, Weibo Liu
Abstract:
To address the challenges in fault location in distribution networks, the distribution of magnetic field under overhead line and its relationship with three-phase currents are explored in this paper. At the same time, considering the influence of sensor installation position, line sag and galloping on magnetic field, a grounding fault location method of an overhead line based on dual-axis magnetic field trajectory is proposed. The analytical expressions of the magnetic field on the x-axis and y-axis under the overhead line are obtained by least squares fitting. The Lissajous figure synthesized by dual-axis is then compared with the general equation of an ellipse, and the characteristic quantity expression characterizing the magnetic field trajectory structure is obtained. Finally, a fault location criterion is constructed using the difference of the characteristic quantities of the ellipses synthesized by x-axis and y-axis magnetic fields upstream and downstream of the fault point, i.e., the difference of the length of the major axis and the minor axis, and the sign for the ratio of the cosine value of the inclination angle. Compared with other location methods based on electrical quantity, the principle of this method is simpler and it can locate faults more quickly and accurately. A large number of simulation results show that the proposed method is suitable for different types of fault conditions.
Key words:  Magnetic feld, Fault location, Lissajous fgure, Distribution network