引用本文:许婷苇,张海强,林 圣,等.基于特征谐波电流积分比值的HVDC整流站保护优化方案[J].电力系统保护与控制,2022,50(7):126-134.
XU Tingwei,ZHANG Haiqiang,LIN Sheng,et al.A novel optimization scheme for HVDC rectifier station protection based onan integral ratio of characteristic harmonic current[J].Power System Protection and Control,2022,50(7):126-134
【打印本页】   【下载PDF全文】   查看/发表评论  【EndNote】   【RefMan】   【BibTex】
←前一篇|后一篇→ 过刊浏览    高级检索
本文已被:浏览 5839次   下载 1716 本文二维码信息
码上扫一扫!
分享到: 微信 更多
基于特征谐波电流积分比值的HVDC整流站保护优化方案
许婷苇1,张海强2,林 圣1,郑 涛3
(1.西南交通大学电气工程学院,四川 成都 611756;2.南京南瑞继保电气有限公司,江苏 南京 211102; 3.新能源电力系统国家重点实验室(华北电力大学),北京 102206)
摘要:
针对现有高压直流输电(HVDC)系统换流站保护在区外交流系统故障时误动作的问题,提出了基于特征谐波电流积分比值的HVDC整流站保护优化方案。此方案利用换流变压器一次侧与送端交流线路的特征谐波电流积分比值来识别整流站区内外故障。当发生整流站区内故障时,该比值大于1;当发生整流站区外故障时,该比值小于1。进而考虑整流站保护与区外交流系统保护在时间上的协调配合,设计了防止整流站保护在区外交流系统故障时的误动作策略。仿真结果表明,所提保护优化方案可以准确识别区内外故障,且不受故障类型、故障距离、过渡电阻、故障初始角以及噪声干扰的影响。
关键词:  高压直流输电  特征谐波  谐波电流积分比值  故障识别  整流站保护优化
DOI:DOI: 10.19783/j.cnki.pspc.211013
分类号:
基金项目:四川省重点研发计划项目资助(2020YFG0063);新能源电力系统国家重点实验室开放课题(LAPS20007)
A novel optimization scheme for HVDC rectifier station protection based onan integral ratio of characteristic harmonic current
XU Tingwei1, ZHANG Haiqiang2, LIN Sheng1, ZHENG Tao3
1. School of Electrical Engineering, Southwest Jiaotong University, Chengdu 611756, China; 2. NR Electric Co., Ltd., Nanjing 211102, China; 3. State Key Laboratory of Alternate Electrical Power System with Renewable Energy Sources (North China Electric Power University), Beijing 102206, China
Abstract:
The existing converter station protection of high-voltage direct current transmission (HVDC) system has the problem of misoperation when external faults occur. Based on the integral ratio of characteristic harmonic currents, a protection optimization scheme for HVDC rectifier stations is proposed. In this scheme, the characteristic harmonic current ratio between the primary side of the converter transformer and the AC line at the transmission end is used to identify the internal and external faults. The ratio is greater than 1 when the internal fault occurs, and the ratio is less than 1 when the external fault occurs. Then the time coordination between the protection of the rectifier station and the outside AC system is designed to prevent misoperation of rectifier station protection in the case of AC system failure outside the zone. Simulation results show that the proposed protection optimization scheme can accurately identify internal and external faults, and is not affected by fault type, fault distance, transition resistance, fault initial angle, and noise interference. This work is supported by Key Research and Development Project of Sichuan Province ( No. 2020YFG0063).
Key words:  HVDC transmission  characteristic harmonics  harmonic current integral ratio  fault identification  rectifier station protection optimization