引用本文:马天祥,王春英,贾静然,等.基于二进制粒子群算法的交直流混合配电网故障恢复方法[J].电力系统保护与控制,2019,47(9):112-119.
MA Tianxiang,WANG Chunying,JIA Jingran,et al.Fault recovery method for AC/DC hybrid distribution network based on binary particle swarm optimization algorithm[J].Power System Protection and Control,2019,47(9):112-119
【打印本页】   【下载PDF全文】   查看/发表评论  【EndNote】   【RefMan】   【BibTex】
←前一篇|后一篇→ 过刊浏览    高级检索
本文已被:浏览 4697次   下载 2207 本文二维码信息
码上扫一扫!
分享到: 微信 更多
基于二进制粒子群算法的交直流混合配电网故障恢复方法
马天祥1,王春英2,贾静然1,段 昕1,程 肖3
(1.国网河北省电力有限公司电力科学研究院,河北 石家庄 050021;2.河北创科电子科技有限公司, 河北 邯郸 056000;3.河北省送变电有限公司,河北 石家庄 050051)
摘要:
针对交直流混合配电网特殊的网架结构和电气特性,构建交直流混合配电网故障恢复模型。所提出的模型以故障恢复综合满意度指标为目标函数,并计及潮流约束、节点电压约束、支路传输约束和网络辐射状约束等约束。对所建立的模型设计两阶段优化求解流程,第一阶段采用二进制粒子群算法进行求解,第二阶段采用粒子群算法进行求解。最后通过一个算例表明,交直流混合配电网故障位置对故障恢复策略以及故障恢复综合满意度指标有着较大影响,同时所提出的模型适用于交直流混合配电网故障恢复问题。
关键词:  交直流混合配电网  故障恢复  两阶段优化  二进制粒子群算法
DOI:10.7667/PSPC180738
分类号:
基金项目:国家电网公司总部科技项目资助(kj2018-063)
Fault recovery method for AC/DC hybrid distribution network based on binary particle swarm optimization algorithm
MA Tianxiang1,WANG Chunying2,JIA Jingran1,DUAN Xin1,CHENG Xiao3
(1. State Grid Hebei Electric Power Research Institute, Shijiazhuang 050021, China;2. Hebei Chuangke Electronics CO.LTD, Handan 056000, China;3. Hebei Electricity Transmission &Transformation Facilities Company, Shijiazhuang 050051, China)
Abstract:
According to the special grid structure and electrical characteristics of AC/DC hybrid distribution network, a fault recovery model of AC/DC hybrid distribution network is constructed. The proposed model takes the fault recovery comprehensive satisfaction index as the objective function, while considering the power flow constraint, the node voltage constraints, the branch transmission constraints, the network radiation constraint, and so on. A two-stage optimization process is designed to solve the established model. In the first stage, the binary particle swarm optimization is used to solve the problem, then the second stage optimization is solved by particle swarm optimization. Finally, an example shows that the fault location of AC/DC hybrid distribution network has a great influence on the fault recovery strategy and the fault recovery comprehensive satisfaction index, and it is applicable to the fault recovery of AC/DC hybrid distribution network. This work is supported by Science and Technology Project of the Headquarter of State Grid Corporation of China (No. kj2018-063).
Key words:  AC/DC hybrid distribution network  fault recovery  two-stage optimization  binary particle swarm optimization