引用本文:徐伟,夏小琴,赵静波,等.基于电气距离的低频振荡关联区域和模式类型识别[J].电力系统保护与控制,2018,46(2):24-30.
XU Wei,XIA Xiaoqin,ZHAO Jingbo,et al.Relevant zone and mode type identification based on electrical distance for low frequency oscillation[J].Power System Protection and Control,2018,46(2):24-30
【打印本页】   【下载PDF全文】   查看/发表评论  【EndNote】   【RefMan】   【BibTex】
←前一篇|后一篇→ 过刊浏览    高级检索
本文已被:浏览 6419次   下载 2642 本文二维码信息
码上扫一扫!
分享到: 微信 更多
基于电气距离的低频振荡关联区域和模式类型识别
徐伟1,夏小琴2,赵静波1,鲍颜红2
(1.国网江苏省电力公司电力科学研究院,江苏 南京 211103;2.南瑞集团公司,江苏 南京 211106)
摘要:
对于低频振荡在线分析得到的若干个振荡模式,调度运行人员需要掌握典型振荡模式的阻尼水平,在紧急状态下根据振荡模式的类型和关联区域采取控制策略。提出了一种基于电网运行分区间电气距离的关联区域和模式类型识别方法,自动识别参与振荡两群机组的关联区域,区分局部振荡模式和区域间振荡模式。通过拓扑分析确定电网的运行分区,选取电压等级最高的母线作为每个运行分区的代表母线。将振荡模式两群关联机组所属的运行分区作为各群的关联运行分区,通过多端口网络等值计算各运行分区代表母线间的电气距离。将同一群中电气距离较近的运行分区进行聚合得到振荡模式两群的关联区域,根据两群关联区域间的电气距离区分局部振荡模式和区域间振荡模式。通过对实际电网在线数据的案例分析验证了该方法的有效性。
关键词:  低频振荡  振荡模式  运行分区  电气距离  关联区域  局部振荡  区域间振荡
DOI:10.7667/PSPC162105
分类号:
基金项目:中国博士后科学基金(2016M591738);江苏省博士后科研资助计划项目(1601160C);国网江苏公司科技项目“特高压直流故障处置后期负荷恢复策略研究”
Relevant zone and mode type identification based on electrical distance for low frequency oscillation
XU Wei1,XIA Xiaoqin2,ZHAO Jingbo1,BAO Yanhong2
(1. State Grid Jiangsu Electric Power Company Research Institute, Nanjing 211103, China;2. NARI Group Corporation, Nanjing 211106, China)
Abstract:
Low frequency oscillation online analysis will obtain a number of oscillation modes. Dispatching operators need to distinguish typical oscillation modes and take actions to improve mode damping in emergency state based on mode type and relevant zone. A method based on electrical distance between operating districts is proposed to identify relevant zone and mode type, operating districts of power grid are determined through topological analysis, representative bus with highest voltage level is selected for each operating district. Buses with higher participation factor are chosen as strong correlative buses and divided into two clusters according to the angle of mode shape. Each cluster will be associated with the operating districts corresponding to strong correlative buses. Electrical distance of representative buses is calculated by multi-port equivalence. Relevant zones of two clusters are obtained by aggravating operating districts with smaller electrical distance. Local oscillation mode and inter-area oscillation mode can be discriminated based on electrical distance between operating districts with buses of largest participation factor in each cluster. The effectiveness of the method has been verified by the cases of actual power grid. This work is supported by China Postdoctoral Science Foundation (No. 2016M591738) and Postdoctoral Science and Research Program of Jiangsu Province (No. 1601160C).
Key words:  low frequency oscillation  oscillation mode  operating district  electrical distance  relevant zone  local oscillation  inter-area oscillation
  • 1
X关闭
  • 1
X关闭