引用本文:许正平,李俊.双向全桥DC-DC变换器高效能控制研究与实现[J].电力系统保护与控制,2016,44(2):140-146.
XU Zhengping,LI Jun.Research and implementation of bidirectional full bridge DC-DC converter with high-efficiency control[J].Power System Protection and Control,2016,44(2):140-146
【打印本页】   【下载PDF全文】   查看/发表评论  【EndNote】   【RefMan】   【BibTex】
←前一篇|后一篇→ 过刊浏览    高级检索
本文已被:浏览 5245次   下载 2623 本文二维码信息
码上扫一扫!
分享到: 微信 更多
双向全桥DC-DC变换器高效能控制研究与实现
许正平, 李俊
南京工业大学电气工程与控制科学学院,江苏 南京 211816
摘要:
针对变换器传统单移相控制的不足之处,分析了双重移相控制下双向全桥DC-DC变换器的功率传输特性。在变压器匝比不为1的条件下,建立了双重移相控制下变换器的通用低频小信号模型。对比了单移相控制方式,仿真结果显示了双移相控制有较小的功率损耗。最后,搭建了实验样机,实验结果证实了该控制方式的高效性和可行性,拓宽了变换器变比的选择范围,具有一定工程应用价值。
关键词:  移相控制  低频小信号模型  高效能  全桥DC-DC变换器  实验样机
DOI:10.7667/j.issn.1674-3415.2016.02.020
分类号:
基金项目:
Research and implementation of bidirectional full bridge DC-DC converter with high-efficiency control
XU Zhengping, LI Jun
College of Electrical Engineering and Control Science, Nanjing Tech University, Nanjing 211816, China
Abstract:
Aiming at the shortcomings of converter under traditional single phase-shift control, this paper analyzes the power transmission characteristics of bidirectional full bridge DC-DC converter with dual phase-shift control. On the condition that ratio of the transformer is not 1, the general low frequency small signal model of converter with dual phase-shift control is built. Compared with single phase-shift control, simulation results show that the loss power of dual phase-shift control is smaller. Finally, the experimental prototype is built, the experimental results confirm the feasibility and efficiency of this control mode. It broadens the range of selection of ratio of the converter, and has certain value in engineering application.
Key words:  phase-shift control  low frequency small signal model  high efficient  full bridge DC-DC converter  experimental prototype