应用于EMS高级应用系统的BPA程序快速调用方法与接口设计
郭文鑫1, 余志文1, 赵峰2, 孙宏斌2, 郭庆来2
1.广东电网电力调度控制中心,广东 广州 510600;2.电力系统国家重点实验室,清华大学电机系,北京 100084
摘要:
针对电网EMS系统中各个高级应用模块在调用BPA暂态计算程序时出现的接口程序继承性差、接口程序调用效率低下的不足,提出了一种快速有效调用BPA暂态计算程序的接口设计方法。通过设定统一的BPA暂态计算程序接口调用模式和文件交互标准,解决了BPA暂态计算程序接口继承性差的问题。同时,根据EMS高级应用调用BPA暂态计算程序的特点,设计了一种快速调用BPA暂态计算程序的接口设计方法,实现了BPA暂态计算程序的快速调用。利用精细规则自动发现系统在广东省电网调用BPA暂态计算程序的算例测试表明:该接口程序能够提供继承性强的BPA暂态计算程序的接口程序,并且可以实现BPA暂态计算程序的快速调用。
关键词:  BPA暂态计算程序  EMS高级应用  接口设计  精细规则自动发现系统
DOI:10.7667/j.issn.1674-3415.2014.11.010
分类号:
基金项目:国家杰出青年科学基金(51025725);广东电网公司科技项目(K-GD2012-303)
An interface applied on advanced application system in EMS for calling BPA transient calculation program quickly and effectively
GUO Wen-xin1, YU Zhi-wen1, ZHAO Feng2, SUN Hong-bin2, GUO Qing-lai2
1.Guangdong Electric Power Control Center, Guangzhou 510600, China;2.State Key Lab of Power Systems, Dept of Electrical Engineering, Tsinghua University, Beijing 100084, China
Abstract:
There are several shortcomings, such as poor succession and low efficiency, when BPA transient calculation program is called by some advanced application systems in EMS through tradition interface. In order to solve these shortcomings, an interface designed for calling BPA transient calculation program quickly and effectively is proposed. Through setting unified BPA transient calculation program interface file interaction standard, the shortcoming of poor succession is solved. According to the features of the advanced application systems in EMS, a method to call the BPA transient calculation program quickly and effectively is designed to call the BPA interface more quickly and effectively. A test case is done in Guangdong Power Grid of China to call the BPA transient calculation program interface using the fine operational rules online automatic discovery system. The results show that the designed interface for calling BPA transient calculation program has good succession and high efficiency, can call the BPA transient calculation program more quickly and effectively.
Key words:  BPA transient calculation program  advanced application systems in EMS  designed interface  fine operational rules online automatic discovery system