摘要:
广域后备保护利用电网线路IED和母线IED采集各元件相关信息,构造基于PSO-LIBSVM的线路和母线故障识别网络。以IED采集的信息作为输入向量,建立故障识别网络的训练样本矩阵;PSO算法寻找最优LIBSVM运行参数并训练故障识别网络,利用随机故障下的测试样本矩阵对线路和母线识别网络进行测试,以识别电网故障元件IED,进而确定故障元件。通过大量实验仿真了多种信息不准确情况下的故障识别,实验证明基于PSO-LIBSVM的广域后备保护新算法,识别准确率高,具有很好的容错性。
关键词:  广域后备保护  线路IED  母线IED  PSO-LIBSVM  故障识别  容错性
DOI:10.7667/j.issn.1674-3415.2013.15.008
分类号:
基金项目:人工智能四川省重点实验室项目(2010RY005,2011RZY02, 2011RYY08);四川省教育厅项目(11ZB100);四川理工学院培育项目(2012PY18)资助
A new algorithm of wide-area backup protection based on PSO-LIBSVM
WU Hao,LI Qun-zhan,LIU Wei
Abstract:
The related information of different power system element may be collected by line IED and bus IED for wide-area backup protection, then the fault recognition network of line and bus based on PSO-LIBSVM is established and the information collected by IED is taken as input vector for establishing the training sample matrix of the fault recognition network. PSO algorithm is used to search optimal parameter combination to train the fault identification network. The line and bus identification network is tested by the testing sample matrix of random failure, and the fault component IED is identified and the fault components are determined. A large number of experiments are made to simulate the fault identification under a variety of inaccurate information. Experiment results show that wide area backup protection based on PSO-LIBSVM has good accuracy and good fault-tolerance.