| 引用本文: | 金义雄,程浩忠.六相电力系统的故障计算方法[J].电力系统保护与控制,2005,33(1):10-15. |
| JIN Yi-xiong,CHENG Hao-zhong.Fault calculation method for six-phase transmission system[J].Power System Protection and Control,2005,33(1):10-15 |
|
| 摘要: |
| 介绍了一种基于模态的六相电力系统的故障计算方法,利用六相系统的对称性,通过对阻抗阵进行变形,使其解耦成两组三相系统,并分别对这两组三相系统采用不对称故障的分析方法,将其组成六相系统的复合序网,以此对其进行不对称短路故障的计算。 |
| 关键词: 六相输电 短路计算 不对称故障 |
| DOI:10.7667/j.issn.1674-3415.2005.01.002 |
| 分类号: |
| 基金项目: |
|
| Fault calculation method for six-phase transmission system |
|
JIN Yi-xiong1,2,3, CHENG Hao-zhong
|
|
1.Shanghai Jiaotong University;2.Shanghai 200030;3.China
|
| Abstract: |
| This paper introduces a model based fault analysis method for six-phase transmission system. Using basic symmetry properties of six-phase transmission line, this paper firstly transforms the impedence matrix to two uncoupled three-phase systems, and then calculates the two systems with asymmetrical fault analysis method respectively, finally does asymmetrical short-circuit calculation after composing the two systems into six-phase compound sequence system. |
| Key words: six-phase transmission short-circuit calculation asymmetry fault |